Showing results: 391 - 405 of 427 items found.
-
Extech MG310 -
Extech Instruments Corporation
The MG310 is a Compact Insulation Resistance Tester which allows quick and easy testing/troubleshooting of motors, transducers, and other industrial appliances. Wide range measurement up to 1000V with Insulation Resistance to 5.5GΩ. Includes an easy snap on protective hard cover and soft pouch to conveniently transport your meter and accessories to the next job site or to safely store away. Featuring Low Resistance measurement with Zero function, Continuity beeper, Large 2000 count dual display with backlight, High voltage and overload indication, Auto-discharge and voltage output warning functions as well as Low battery indication. Complete with test leads, alligator clips, 6 x AA batteries, hard cover, and soft carrying case.
-
448 -
SCI
Our 448 model is a 4-in-1 tester with 500VA AC Hipot, DC Hipot, Insulation Resistance and Ground Bond testing capabilities. The 448 is capable of a 500VA AC Hipot output to comply with 100mA leakage current test compliance requirements. This tester features a simple design and easy-to-use interface, reducing setup time and increasing production-line throughput for your application.
-
MB Model -
PJ Electronics, Inc.
Bench all-in-one versatile Multi-Operational Surge Tester that you need for all of your electrical insulation testing. The Hi-Pot tester has separate L.E.D. panel meters for direct readout (voltage and leakage current) so that no interpolation on the scopes display is ever needed. This MOST can surge test extremely low inductance windings, DC armatures, etc.
-
AMPI-530 -
Amperis sl
Measurement of short-circuit loop ; Testing of differential, general and selective protections for differential current ; Measurement of insulation resistance ; Up to 10GΩ ; Voltages: 50 V, 100 V, 250 V, 500 V, 1000 V ; Measurement of earth resistance ; Bi-directional continuity test on PE cables, phase sequence ; Measurement and recording of voltage, frequency, alternating current, cosϕ, power, harmonics and THD
-
440 Series -
SCI
The 440 Series provides advanced 4-in-1 test capability in a convenient one-box solution. This new series performs AC Hipot (448 - 500 VA), DC Hipot, Insulation Resistance and 40A AC Ground Bond tests while taking up minimal production line space. The 440 Series is simple and easy-to-use; reducing setup time and increasing production line throughput for your application. With multiple memories and an optional USB port for remote BUS communication so you can quickly perform tests on a variety of DUTs from the front panel or with a PC. Learn about our 5 Year Warranty.
-
A694 -
AGM Elettronica
The A694 is a short circuit locator designed for fault location in metallic cables. The instrument measures the ratio of the resistances of the two sections of failed conductor using a four-wire "Kelvin" connection, thus eliminating errors associated with contact resistances of the test leads. With the A694 you can determine if the cable has more than a short and locate the first and the last fault. The instrument locates fault with an insulation resistance up to 5 Mohms in cables that have a total resistance greater than 0.1 ohm and less than 40 kohms. The distance to fault is measured as a percentage of the total length of cable and is displayed on a large LCD display.
-
Xitron Technologies Inc.
Vitrek hipot testers serve a range of different industries and are designed by experts who have made the company a global leader for supporting electrical safety tests. Each series of hipot testers is designed to handle AC and DC hipot, and select models can also measure IR insulation resistance. Vitrek manufactures two different series of hipot and electrical safety testers. These hipot testers have been designed to fit your testing application. Each series offers 6 different models with a wide variety of electrical safety test functions and capabilities.
-
72-1015 CAL -
Tenma
The 72-1015 CAL from Tenma is a digital bench type true RMS multimeter. It has auto and manual range options with maximum reading of 5999 counts and 3-5/6 digits which has a unique outlook design. In addition to all the conventional features including DC/AC voltage, current, resistance, diode, continuity test, diode test capacitance, temperature, transistor, max/min, there is a data hold, low battery display, sleep mode, RS232C serial port for easy connection with computer to realize macro recording, monitoring and capture of transient dynamic data, displaying change of waveform during the measurement, providing data and evidence to engineering technicians for scientific research. This meter complies with the standards IEC61010, pollution degree 2, overvoltage category (CAT I 1000V, CAT II 600V) double insulation and CE marked.
-
72-1015 CAL D -
Tenma
The 72-1015 CAL D from Tenma is a digital bench type true RMS multimeter. It has auto and manual range options with maximum reading of 5999 counts and 3-5/6 digits which has a unique outlook design. In addition to all the conventional features including DC/AC voltage, current, resistance, diode, continuity test, diode test capacitance, temperature, transistor, max/min, there is a data hold, low battery display, sleep mode, RS232C serial port for easy connection with computer to realize macro recording, monitoring and capture of transient dynamic data, displaying change of waveform during the measurement, providing data and evidence to engineering technicians for scientific research. This meter complies with the standards IEC61010, pollution degree 2, overvoltage category (CAT I 1000V, CAT II 600V) double insulation and CE marked.
-
72-1015 CAL DU -
Tenma
The 72-1015 CAL DU from Tenma is a digital bench type true RMS multimeter. It has auto and manual range options with maximum reading of 5999 counts and 3-5/6 digits which has a unique outlook design. In addition to all the conventional features including DC/AC voltage, current, resistance, diode, continuity test, diode test capacitance, temperature, transistor, max/min, there is a data hold, low battery display, sleep mode, RS232C serial port for easy connection with computer to realize macro recording, monitoring and capture of transient dynamic data, displaying change of waveform during the measurement, providing data and evidence to engineering technicians for scientific research. This meter complies with the standards IEC61010, pollution degree 2, overvoltage category (CAT I 1000V, CAT II 600V) double insulation and CE marked.
-
EN 60601 -
LXinstruments GmbH
Test system for electrical safety compliance testing of medical products in accordance with EN 60601-1, 3rd edition.The system is equipped with three test fixtures which are connected in parallel order to reduce the number of setup tasks for different variants in the course of day-to-day manufacturing processes. Its purpose is to test medical products, e. g. patient monitors, which are employed at hospitals to monitor heartbeat and oxygen saturation.Based on the integrated electrical safety tester by Associated Research, in combination with an AC power source and a switching matrix, it is possible to fully automate tests like for instance AC/DC high-voltage tests, insulation resistance measurements, earth connection tests and leakage current measurements.The required occupational safety is provided by a high-voltage safety hood in accordance with EN 501191. The entire safety technology, as well as the control PC, is mounted in an aluminum-profile cart.
-
A910 -
AGM Elettronica
The A910 is a short circuit locator designed for fault location in power cables. The instrument measures the ratio of the resistances of the two sections of failed conductor using a four-wire "Kelvin" connection, thus eliminating errors associated with contact resistances of the test leads. With the A910 you can determine if the cable has more than a short and locate the first and the last fault. The instrument locates fault with an insulation resistance up to 5 Mohms in cables that have a total resistance greater than 5mohm (approximately 90 m of 300 sqmm cable) and less than 30 kohms. The distance to fault is measured as a percentage of the total length of cable and is displayed on a large LCD display.
-
DEL-101 -
Standard Electric Works Co., Ltd
● Mains wiring polarity check.● ELCB/RCD testing.● Measuring ear for line current.● Measuring ear for leakage current.● Helps calculate insulation resistance.● Helps calculate power consumption.● Helps fault finding of standing earth fault.● Fused main adapter.● Appliance testing (with the aid of a clamp meter).● Fused appliance socket.● No batteries required.● HRC fuse inside.● Fused, color-coded universal test sockets.● Universal mains IEC Lead.
-
Instron
These three zone resistance wire wound furnaces are of split construction to facilitate fast and easy loading of a pre-assembled specimen train. The case is constructed from stainless steel with aluminium and hardened insulation board end plates. The optional front cut-out allows the use of side-entry high-temperature extensometry. Adjustable stainless steel latches keep the furnace halves locked together during use, but are then easily opened once testing is complete. The furnace is available with optional heavy duty brackets or mountings, which attach to a wide range of testing systems. An extensive range of standard controllers is available to suit most test regimes. Custom variants can be specified should the standard range not include a suitable unit.
-
DMC, Inc.
DMC's Battery Pack Test Systems facilitate battery design as well as research and development for national laboratories and research institutions. They are deployed in end of line / production test stations for battery packs developed by major automotive manufacturers and their suppliers. DMC's battery pack test systems are designed to evaluate the battery as a complete system and validate a comprehensive range of battery pack functionalities, including:Power performance, Capacity, DCR / Internal ResistanceContactor and safety interlock functionsIsolation / Insulation ResistancesReporting of operating data through external communication interfaces (usually CAN)Cell VoltagesPack / Cell TemperaturesState of ChargeFaults / Diagnostic Trouble Codes (DTCs)Etc.Electrical characteristics / continuity of internal pack wiring / signalsCooling system operation